XD-series crawler DTH rig operates continuously in highly-dusty, rock-impact mine and quarry environment. Standard maintenance reduces unplanned downtime and extends service life of main unit, hydraulic parts and drilling assemblies.

Pre-Shift Inspection

  1. Check crawler tension, track shoes and rollers for wear or damage.
  2. Inspect hydraulic hoses and fittings for leakage; check tightness of all bolts.
  3. Service dust-collector unit, clean filter element and ensure unobstructed airflow.
  4. Verify oil, fuel and coolant level of power unit.
  5. Inspect mast and feed guide; check thread condition of DTH hammer, drill rods and bits.

Post-Shift Maintenance

  1. Clean rock dust and debris from machine, crawlers and mast to avoid abrasive wear on moving parts.
  2. Apply grease to all hinge and pivot points.
  3. Empty dust from dust-collector box.
  4. Inspect drilling tools for wear and store properly.

Note: Avoid sustained over-load forced drilling. Stop operation in case of abnormal noise, oil leakage or poor dustcollection performance. Contact manufacturer technical support for major failures.

Get A Quote?

If you are interested in any of our products or would like to make your customized order, please feel free to contact us. We are looking forward to establish successful business relations with you.

Quick Links

Quick Links

Overssale Business

Overssale Business

Tel: +86 714 3860 269

Phone: +86 189 8659 6914

WhatsApp: +86 189 8659 6914

WeChat: +86 189 8659 6914

Email: sales@xingdamachinery.com

ADD: No 7and 8 Factory, #9 Bingang Road, Ezhou, Hubei Province, China

Get The Latest News

Get The Latest News

Copyright © Hubei Xinda Drilling Machinery Equipment Co.,Ltd. All Rights Reserved. | Sitemap